PUR 98 W
Wall mounted cooker hood with energy-efficient LED lighting and light-touch switches for easy use.
Product data sheet
Construction type
Wall mounted cooker hood | • |
Operating modes
Type of air guide | Convertible |
Recirculation conversion kit (order separately) | DUW 20 |
Active charcoal filter (order separately) | DKF12-1 |
Design
Colour | Stainless steel |
RAL colours available as customisation on request | • |
Customisation possible on request | • |
Variable height available as customisation on request | • |
Variable width available as customisation on request | • |
User convenience
Electronic controls | • |
Light-touch switches with LED | • |
Power levels (number without Booster level) | 3 |
Programmable Booster level switch-off | • |
Easy-to-clean canopy interior – CleanCover | • |
Efficiency and sustainability
Energy efficiency class | A |
Energy efficiency class (A+++ to D) | A |
Annual energy consumption in kWh/year | 49.70 |
Fluid dynamic efficiency class | A |
Lighting efficiency class | A |
Grease filtering efficiency class | A |
Filter system
Number of dishwasher safe stainless-steel grease filters (10-ply) | 3 |
Lighting
LED | • |
Number x W | 3 x 3 W |
Light intensity in Lx | 450 lx |
Colour temperature in K | 3000 Kelvin |
Blower
Dual-action blower | • |
AC motor | • |
Extraction
Air throughput in Level 1 (m³/h) according to EN 61591 | 265 |
Air throughput in Level 2 (m³/h) according to EN 61591 | 320 |
Air throughput in Level 3 (m³/h) according to EN 61591 | 395 |
Air throughput in Booster level (m³/h) according to EN 61591 | 650 |
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 | 47.00 |
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 | 52.00 |
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 | 56.00 |
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 | 67.00 |
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 | 32.00 |
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 | 37.00 |
Sound pressure in setting 3 (dB(A) re 20 µPa) | 41.00 |
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 | 52.00 |
Recirculation
Air throughput in Level 1 (m³/h) according to EN 61591 | 190 |
Air throughput in Level 2 (m³/h) according to EN 61591 | 270 |
Air throughput in Level 3 (m³/h) according to EN 61591 | 330 |
Air throughput in Booster level (m³/h) according to EN 61591 | 460 |
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 | 54.00 |
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 | 60.00 |
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 | 64.00 |
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 | 71.00 |
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 | 39.00 |
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 | 45.00 |
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 | 48.00 |
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 | 56.00 |
Safety
Safety shut-off | • |
Technical data
Overall height for vented and external in in. (mm) | 685 |
Overall height for extraction mode and external mode cooker hoods in mm | 1005 |
Overall height for recirculation in in. (mm) | 815 |
Overall height for recirculation mode cooker hoods in mm | 1135 |
Canopy width in in. (mm) | 898 |
Canopy height in in. (mm) | 62 |
Depth of hood canopy in in. (mm) | 500 |
Minimum height above electric hobs in mm | 450 |
Minimum height above gas hobs (max. 12.6 kW total power, burner ≤ 4.5 kW) in mm | 650 |
Net weight in kg | 25.00 |
Length of supply lead in m | 1.50 |
Standard plug fitted | • |
Total rated load in kW | 0.23 |
Voltage in V | 230 |
Fuse rating in A | 10 |
Frequency in Hz | 50 |
Number of phases | 1 |
Installation notes
Extraction ducting connection at top | • |
Extraction ducting connection at rear | • |
Extraction connection at top and rear | • |
Diameter of extraction ducting connection in mm | 150 |
Telescopic chimney | • |
Standard accessories