CSDA 7001 FL

SmartLine element as downdraft extractor for extraction or recirculation operation
  • Intuitive quick selection via number sequences – Smart Select
  • Elegant design – for flush or raised installation
  • Seamlessly integrates with any SmartLine element
  • Efficient filtration- 10-ply stainless-steel grease filter
  • Energy-efficient and quiet - powerful ECO motor

Product data sheet

Downdraft extractor
Type of air guide Convertible
Extraction mode
Recirculation conversion kit (order separately) DUU 1000-2
Flat ducting components (order separately) DFK- xxxx
Flush
Frameless – surface-mounted
Recirculation mode conversion kit DUU 1000-1
Silencer for 150 mm Ø DASD 150
Wall vent for 150 mm Ø DMK 150
Operation via sensor controls Smart Select
Digital power level display
Display colour Yellow
Run-on time 5 min.
Energy efficiency class (A+++ to D) A++
Annual energy consumption in kWh/year 25.30
Fluid dynamic efficiency class A
Lighting efficiency class -
Grease filtering efficiency class B
ECO motor
Easy to clean ceramic glass
Easy-to-clean canopy interior – CleanCover
Number of dishwasher safe stainless-steel grease filters (10-ply) 1
Air throughput in Level 1 (m³/h) according to EN 61591 150
Air throughput in Level 2 (m³/h) according to EN 61591 290
Air throughput in Level 3 (m³/h) according to EN 61591 440
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 58.00
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 29.00
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 43.00
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 51.00
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 55.00
Air throughput in Level 1 (m³/h) according to EN 61591 100
Air throughput in Level 2 (m³/h) according to EN 61591 235
Air throughput in Level 3 (m³/h) according to EN 61591 380
Air throughput in Booster level (m³/h) according to EN 61591 460
Sound power in Level 1 (dB(A) re 1 pW) according to EN 60704-3 49.00
Sound power in Level 2 (dB(A) re 1 pW) according to EN 60704-3 63.00
Sound power in Level 3 (dB(A) re 1 pW) according to EN 60704-3 73.00
Sound power in Booster level (dB(A) re 1 pW) acc. to EN 60704-3 78.00
Sound pressure in Level 2 (dB(A) re 20 µPa) according to EN 60704-2-13 49.00
Sound pressure in Level 3 (dB(A) re 20 µPa) according to EN 60704-2-13 58.00
Sound pressure in Booster level (dB(A) re 20 µPa) acc. to EN 60704-2-13 63.00
Sound pressure in Level 1 (dB(A) re 20 µPa) according to EN 60704-2-13 34.00
Safety switch-off
FlameGuard
Dimensions in mm (width) 120
Dimensions in mm (height) 168
Dimensions in mm (depth) 520
Casing height incl. connection box in mm 168
Cutout dimensions in mm (width) with surface-mounted installation 100
Cutout dimensions in mm (depth) with surface-mounted installation 500
Inner cut-out dimensions in mm (width) with flush installation 100
Inner cut-out dimensions in mm (depth) with flush installation 500
Outer cut-out dimensions in mm (width) with flush installation 124
Outer cut-out dimensions in mm (depth) with flush installation 524
Weight in kg 11
Total rated load in kW 0.17
Voltage in V 230
Fuse rating in A 10
Number of phases 1
Length of supply lead in m 2
Plinth fan with vent connection
Extraction connection at rear and side
Dimensions of the exhaust ducting connector in mm 222
Dimensions of the exhaust ducting connector in mm 89

What’s included

  • Mains cable with plug
  • Ducting system to the plinth fan
  • Ducting system to the plinth fan